EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY
Product Details
Y-NIR-T500 near infrared spectrometer (transmission type)
Integrated integration, fulY-Featured. Built-in light source, cuvette holder and spectral module, placed cuvette can be directly measured, easy to use. Ultra-small size for easy integration. Very small size, compact and portable to achieve small portable devices. Interface rich, flexible communication. Support MicroUSB, Uart, Bluetooth and other communication methods, can be adapted to PC, development board, single chip microcomputer, mobile phone and other full SDK adaptation, free choice of development platform. C, C#, Labview, Matlab, Qt, Linux, Android and other comprehensive support.
Key words:
Y-NIR-T500 near infrared spectrometer (transmission type)
Classification:
Hotline:
Y-NIR-T500 near infrared spectrometer (transmission type)
Product features:
Integrated integration, fulY-Featured. Built-in light source, cuvette holder and spectral module, placed cuvette can be directly measured, easy to use. Ultra-small size for easy integration. Very small size, compact and portable to achieve small portable devices. Interface rich, flexible communication. Support MicroUSB, Uart, Bluetooth and other communication methods, can be adapted to PC, development board, single chip microcomputer, mobile phone and other full SDK adaptation, free choice of development platform. C, C#, Labview, Matlab, Qt, Linux, Android and other comprehensive support.
Technical parameters:
| Project | Parameters | Description |
| Product Model | Y-NIR-T500 | Integrated measurement of liquid transmission |
| Wavelength range | 900-1700 | Near infrared commonly used wavelength or wavenumber range |
| optical resolution | Type.12 nm,Max.14 nm | Common peak wavelength half-width representation |
| Wavelength accuracy | Type. ± 1 nm,Max ± 2 nm | Wavelength deviation of the measurement peak from the calibration sample peak |
| signal-to-noise ratio | 6000:1 | Ratio of full-scale relative intensity value to system electronic noise fluctuation value |
| Slit size | 25um | Spectrometer entrance slit, mass production built-in, can not be changed |
| Communication Interface | MicroUSB、UART、蓝牙 | MicroUSB direct connection computer, Uart for serial port, Bluetooth for mobile phone APP |
| Sensor | Temperature and humidity sensor | Used to display the internal temperature and humidity value of the module |
| Power supply | 5V-300mA | USB power supply, lithium battery power supply or external power supply |
Divided by product wavelength:
1.900--1700nm;
2.1350--2150nm;
3.1600--2400nm;
4.900--2400nm;
According to the type of product light path:
1. Reflective type;
2. Optical fiber type;
3. Transmission type;

Selection Guide:
| Selection Guide | Solid/Powder | Liquid |
diffuse reflectance spectrometer 900~1700nm: R500 1350~2150nm:R300 1600~2400nm:R320 | Diffuse: Suitable for opaque solids and powders (e. g. tablets) | Transverse (please attach reflective material behind the sample): Suitable for clear liquids (e. g. wine) |
Transverse (please attach reflective material behind the sample): Suitable for transparent solids (e. g. plastic film) | Diffuse: Suitable for suspensions or opaque liquids (e. g. milk) | |
Penetrating spectrometer 900~1700nm:T500 1350~2150nm:T300 1600~2400nm:T320 | Penetrating: Suitable for transparent solids (such as transparent plastic plates) | Penetrating: Suitable for clear liquids (e. g. wine) |
Penetrating type (please use a cuvette with very short optical path): Suitable for suspensions or opaque liquids (e. g. milk) | ||
optical fiber spectrometer 900~1700nm:F50C 1350~2150nm:F300 1600~2400nm:F320 |
The optical fiber spectrometer/module plus light source, optical fiber, probe and other accessories can construct various measurement methods including diffuse reflection, transmission, transmission, interaction, etc. | |


near infrared commonly used measurement optical path:

Previous Page
Next Page
Previous Page
Next Page
Related Products
The Michelson interferometer is a crucial instrument in physics—it not only confirmed Einstein’s postulate of the constancy of the speed of light, but also demonstrated that light can propagate and exhibit interference without requiring a medium—meaning that the so-called "ether," once thought to permeate space, does not exist. Yet, this groundbreaking discovery simultaneously gave rise to a lingering puzzle in physics (often referred to as "a single dark cloud"): if there’s no ether—no medium—how exactly does light travel? And more specifically, how does light produce interference in the first place? As Albert Einstein once remarked, "I’ve always regarded Michelson as an artist among scientists; his greatest joy seemed to stem from the sheer elegance of the experiment itself and the masterful precision of the methods he employed." To scientists, the Michelson interferometer is not just a scientific tool—it’s also a remarkable work of art. For both functionality and aesthetic appeal, the LGS-2 portable Michelson product comes encased in a sleek, transparent acrylic display box, offering dual protection: it shields the instrument from dust while transforming it into a captivating piece of art. After all, this device aims to balance practical utility with artistic value.
A quantum computer is a machine capable of performing quantum computing, leveraging the principles of quantum mechanics to carry out mathematical and logical operations, as well as process and store information. Theoretically, it is a physical system that uses quantum bits (qubits) as its fundamental storage units, with quantum dynamical evolution forming the basis for information computation. Currently, the main technological approaches can be categorized into six types: superconducting, ion-trap, photonic quantum, neutral atoms, silicon spin, and topological.
YGT-5 diode pumped laser principle experimental instrument
This experimental device takes 808nm semiconductor pumped Nd:yv04 laser as the research object. By setting up the whole experimental system and completing each part of the experiment, it can learn the debugging method of semiconductor pumped laser, observe the frequency doubling phenomenon, measure the threshold, phase matching and other experimental test methods. Deepen the understanding of the basic theory of laser principle and optical frequency doubling technology, and realize the combination of theory and practice. Compared with similar products, this experimental instrument has many functions, can set up many experimental contents, mechanical structure is stable and easy to debug, and the experimental operation is strong.
Experimental instrument for YGT-6 pulsed Q-switched Nd:YAG frequency-doubled laser
This experimental device grasps the basic principle, basic structure, main parameters, output characteristics and adjustment methods of the laser by setting and adjusting the laser by hands, and through observing the phenomena of Q-tuning, mode selection, frequency doubling, etc., learners have a more comprehensive understanding of the principle and technology of the laser. This equipment adopts various protection measures to effectively protect the safety of the operator. A variety of experiments can be set up, allow users to fully understand the principle of laser generation.
Online consultation
We will contact you within one working day. Please pay attention to your email.