EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY EPSION TECHNOLOGY
Product Details
Y-F300A fluorescence spectrophotometer
Y-F300A molecular fluorescence spectrophotometer has the characteristics of simple operation and powerful functions, and provides good help for customers to collect and process the fluorescence, luminescence and phosphorescence of various samples. As long as the components of this instrument are selected components, the stability of the whole machine is well improved and the detection sensitivity, fast scanning speed, wide spectral measurement range, large detection dynamic range and fast three-dimensional scanning are ensured. The equipment is mainly used in materials research, drug analysis, water quality testing, food safety, environmental testing and other fields.
Key words:
Y-F300A fluorescence spectrophotometer
Classification:
Hotline:
Y-F300A fluorescence spectrophotometer
Y-F300A molecular fluorescence spectrophotometer has the characteristics of simple operation and powerful functions, and provides good help for customers to collect and process the fluorescence, luminescence and phosphorescence of various samples. As long as the components of this instrument are selected components, the stability of the whole machine is well improved and the detection sensitivity, fast scanning speed, wide spectral measurement range, large detection dynamic range and fast three-dimensional scanning are ensured. The equipment is mainly used in materials research, drug analysis, water quality testing, food safety, environmental testing and other fields.
Instrument features:
● high quality high-quality scanning ensures the accuracy and accuracy of the map. It provides multi-beam spectrum scanning options, with ultra-fast scanning speed up to 30000nm/min, and a perfect data acquisition system to ensure the richness, integrity and accuracy of data points. Three-dimensional scanning, rapid processing and positioning; High-speed digital signal processing technology has reached the leading level and high-quality three-dimensional scanning, more sample analysis, testing, work efficiency is greatly improved.
● Specially designed chopping mechanism: This chopping mechanism is novel in design and unique in structure. Its cooperation with the control system can realize high-precision control of the chopping system, ensure the accuracy of phosphorescence detection, make the phosphorescence test use the characteristics of phosphorescence long life, completely avoid the interference of stray light such as Rayleigh light and Raman light, and achieve an effective constant measurement method.
● Phosphorescence determination: Phosphorescence determination can measure phosphorescence lifetime as short as one millisecond, so it can be applied to various sample types.
● This instrument has a double monochromator system design, and is equipped with emission shutter and light control device, making the test results and stability greatly improved, but also to ensure the service life of the product
● This instrument can test a variety of samples, such as fluorescence, chemiluminescence and phosphorescence and other tests, to meet the needs of users, test mode diversification, including: wavelength scanning, time scanning, photometric scanning, three-dimensional scanning.
Configuration parameters:
| Name | Main parameters |
| Light source | Imported long-life xenon lamp, high-performance regulated light source with automatic ozone removal function. Power: 150W luminous flux: 2900Im, service life is more than 2000 hours, protection grade IP64, software control |
| Wavelength range | 200nm -- 760nm, zero-order light; the wavelength range can be extended to 200nm -- 900nm according to demand |
| monochromator | Monochromator is divided into excitation monochromator and emission monochromator; pure imported three flash grating, 900L\MM |
| signal-to-noise ratio | Water Raman peak P-P, greater than 300:1 |
| Wavelength accuracy | Wavelength accuracy: ± 2.0nm |
| Wavelength Repeatability | Wavelength repeatability: ≤ 1.0nm |
| spectral bandwidth | Excitation: 1.0nm, 2. 0nm, 5.0nm, 10.0nm, 20.0nm; Emission: 1.0nm, 2.0nm, 5.0nm, 10.0nm, 20.0nm |
| Scanning speed | Eight scanning; 30nm, 60nm, 120nm, 240nm, 1200nm, 2400nm, 12000nm, 30000nm/min |
| Response time | 4 milliseconds ~ 8 seconds, with Auto function can be automatically adjusted |
| photometric range | -9999--9999 |
| Gain | Four-speed adjustable |
| Measurement mode | Wavelength scanning, time scanning, photometry, three-dimensional scanning; test function: fluorescence \bio-chemiluminescence, phosphorescence and phosphorescence lifetime. |
| Scan time | When the unit is s, the range is 10~9000ms. |
| Minimum sample size | 10mm standard cuvette, 0.5ml |
Application areas:
● Application of fluorescence spectrophotometry in the determination of vitamin C content in infant food and dairy products, vegetables and fruits and their products.
The application of fluorescence spectrophotometry in the determination of vitamin B1 content in food.
The application of fluorescence spectrophotometry in the determination of vitamin B2 content in food.
The application of fluorescence spectrophotometry in the determination of aflatoxin content in food.
● Application of fluorescence spectrophotometry in the determination of benzo (a) pyrene content in food and water.
The application of fluorescence spectrophotometry in the determination of selenium content in food, feed, water quality and marine organisms.
The application of fluorescence spectrophotometry in the determination of the life of fluorescent materials (LED phosphors, instrument panel fluorescent substances).
The application of fluorescence spectrophotometry in the determination of petroleum hydrocarbon content in marine organisms.
The application of fluorescence spectrophotometry in the determination of quantum dot fluorescent materials.
Previous Page
Next Page
Previous Page
Next Page
Related Products
The Michelson interferometer is a crucial instrument in physics—it not only confirmed Einstein’s postulate of the constancy of the speed of light, but also demonstrated that light can propagate and exhibit interference without requiring a medium—meaning that the so-called "ether," once thought to permeate space, does not exist. Yet, this groundbreaking discovery simultaneously gave rise to a lingering puzzle in physics (often referred to as "a single dark cloud"): if there’s no ether—no medium—how exactly does light travel? And more specifically, how does light produce interference in the first place? As Albert Einstein once remarked, "I’ve always regarded Michelson as an artist among scientists; his greatest joy seemed to stem from the sheer elegance of the experiment itself and the masterful precision of the methods he employed." To scientists, the Michelson interferometer is not just a scientific tool—it’s also a remarkable work of art. For both functionality and aesthetic appeal, the LGS-2 portable Michelson product comes encased in a sleek, transparent acrylic display box, offering dual protection: it shields the instrument from dust while transforming it into a captivating piece of art. After all, this device aims to balance practical utility with artistic value.
A quantum computer is a machine capable of performing quantum computing, leveraging the principles of quantum mechanics to carry out mathematical and logical operations, as well as process and store information. Theoretically, it is a physical system that uses quantum bits (qubits) as its fundamental storage units, with quantum dynamical evolution forming the basis for information computation. Currently, the main technological approaches can be categorized into six types: superconducting, ion-trap, photonic quantum, neutral atoms, silicon spin, and topological.
YGT-5 diode pumped laser principle experimental instrument
This experimental device takes 808nm semiconductor pumped Nd:yv04 laser as the research object. By setting up the whole experimental system and completing each part of the experiment, it can learn the debugging method of semiconductor pumped laser, observe the frequency doubling phenomenon, measure the threshold, phase matching and other experimental test methods. Deepen the understanding of the basic theory of laser principle and optical frequency doubling technology, and realize the combination of theory and practice. Compared with similar products, this experimental instrument has many functions, can set up many experimental contents, mechanical structure is stable and easy to debug, and the experimental operation is strong.
Experimental instrument for YGT-6 pulsed Q-switched Nd:YAG frequency-doubled laser
This experimental device grasps the basic principle, basic structure, main parameters, output characteristics and adjustment methods of the laser by setting and adjusting the laser by hands, and through observing the phenomena of Q-tuning, mode selection, frequency doubling, etc., learners have a more comprehensive understanding of the principle and technology of the laser. This equipment adopts various protection measures to effectively protect the safety of the operator. A variety of experiments can be set up, allow users to fully understand the principle of laser generation.
Online consultation
We will contact you within one working day. Please pay attention to your email.